70
6. General specifications
Measuring mode
TRMS Value
Jaw capacity
Ø26mm (tip shape: 11mm)
Dimensions
188x66x32mm
Weight
202g
Protection degree
IP40
Display
Backlit LCD 6000 counts
Frequency response
50Hz…400Hz
Operating environmental conditions
0°C…+40°C; max 80% RH without condensation
Measurement category
CAT IV-300V, CAT III-600V
Power supply
2 batteries AAA 1.5V
Temperature coefficient
0.1 x measurement accuracy/°C
(in the intervals 0°C…+18°C and +28°C…+40°C)
Display refresh
5 times/second
Overload protection
- Current: 600A DC/ACrms up to 400Hz
- Voltage: 660VDC and 920VACrms
- Other functions: 600V DC/ACrms
Crest factor
Up to 2 on the full scale, up to 4 on the center scale
Input impedance under voltage
10 M
Ω
, 100 pF
Open-circuit voltage in resistance
1.0Vdc typical
Consumption
4mA typical
Indication of low batteries
<2.85V
APO Timing
32 minutes idle
APO Consumption
5uA typical
Pollution degree
2
Storage environmental conditions
-20°C…+60°C; max 80% RH no condensation (without
batteries)
Maximale Höhe
2.000 m.ü.Msp.
Manufacturing standards
EN 61010-1: 2013
EN 61010-031: 2015
EN 61010-2-032: 2013
EN 61010-2-033: 2014
EN 61326-1: 2013
71
7. Measurement functions and accuracy
Function
Measurement
range
Basic accuracy
(bei 23°C ± 5°C)
Notes
DC Voltage
600.0 V
±1.0% rdg ± 5 dgt
–
AC Voltage
600.0 V
(50…60 Hz)
±1.5% rdg ± 5 dgt
–
DC Current
60.00 A
(tip sensor)
±1.0% rdg ± 5 dgt
1) 2) 3)
1)Error due to current on adjacent
cables: <0.01A/A
2) Having carried out the reset
operation
3) Add 4 dgt for measurements <4A
600.0 A
(sensor on the
center of the jaw)
±2.0% rdg ± 5 dgt
1) 2)
AC Current
60.00A
(tip sensor)
(50…60 Hz):
±1.0% rdg ± 5 dgt
1)
1) Fehler aufgrund von Strom
auf benachbarten Leitungen:
<0,01A/A
600.0A
(sensor on the
center of the jaw)
(50…100 Hz):
±1.5% rdg ± 5 dgt
1)
(100…400 Hz): ±2.0%
rdg ± 5 dgt
1)
Resistance
600.0
Ω
±1.0% rdg ± 5 dgt
–
6.000 k
Ω
±1.0% rdg ± 5 dgt
Crest value meas-
urement (>5 ms)
–
–
For voltage and current: add
±250dgt to the range accuracy
Diode test
–
–
Test current 0.3mA, Open-circuit
voltage <3.5Vdc
Continuity test
–
–
Threshold between 30
Ω
uand
300
Ω, response time 15ms, acoustic
and optical signal
Non-contact
voltage detection
–
–
2 sensitivity thresholds selectable be
-
tween H and L (detection frequency:
50/60Hz)
MAX/MIN recording, peak current measurement (5ms) with recording of MAX and MIN crest values,
HOLD function, single pole phase locator function, non-contact voltage detector (NCV), acoustic and
optical signal, diode test, continuity test, relative value measurement.
Summary of Contents for 0715 53 75
Page 2: ...2 IT 3 25 DE 27 49 GB 51 74 ...
Page 26: ...26 IT 3 25 DE 27 49 GB 51 74 ...
Page 50: ...50 IT 3 25 DE 27 49 GB 51 74 ...