Installation and Setup
Fan Module Installation
Installation and Setup
WMDKdoc020322
3-4
3
3.4
Fan Module Installation
In this installation process we will describe the process for a 20’ kiln with 4
modules.
NOTE:
All references to right and left are as viewing the kiln chamber from the door end.
CAUTION!
The fans can work at temperatures not exceeding 60
o
C
The fan module has already been pre-assembled at the factory and no further assembly is
required during the installation.
for instructions on how to connect the fan
modules to the control box.
Four (4) fan module units are required for a 20’ kiln.
First install the fourth module (marked “4” in the left bottom corner):
Drill holes for the module mounting strip in the chamber roof. Use two people to do
it. One person should place the module with bolted strip in the rear right hand corner
of the chamber and hold it in this position and the other person should drill through
the 5 holes into the roof. Remove the fan module and unbolt the module from the
strip. Re-position the strip to the roof and rivet the strip using the holes already
drilled. Now, position the fan module to the strip and bolt together.
NOTE:
You can
also drill the holes for the mounting strip using the dimensions indicated in figure
below.
FIG. 3-2
WDK033
Module no.