Installation and Setup
Control Box Installation
3
3-11
WMDKdoc020322
Installation and Setup
3.6
Control Box Installation
DANGER!
Make sure all electrical installation, service
and/or maintenance work is performed by a qualified
electrician and is in accordance with EN 60204 Standard.
NOTE:
Mounting in the isothermal container is shown on the pictures below.
The control box must be installed on the outside wall of the kiln chamber on the right hand
side from the door, at least 1250mm from the front chamber edge (which will prevent the
chamber door from hitting the electric box) and about 1200mm above the ground (the
display should be at the operator’s eye level).
To install the control box to the kiln, position the electric box as described above and then
mark and drill the control box mounting holes. Drill only through the outer skin of the kiln
using the 11 mm drill bit provided. Next, install the M8 rivet nuts using the rivet gun
provided (the squeeze size on the riveter indicator should be set at 1 mm).
FIG. 3-7