Maintenance
Festoon Replacement
5
5-28
HD-Rdoc072619
Maintenance
5.
Replace the exiting pulley and the bushing located at the upper pulley mount with the pro-
vided pulley. Use the provided hex head bolt, the provided fender washer, the existing
washers and the hex nylon lock nut to secure the pulley to the upper pulley mount as
shown below.
See Figure 5-16.
6.
Unlock and open the distribution box.
FIG. 5-16
600378-11
Upper Pulley Mount
Pulley
Nylon
Lock Nut
1/2” Flat
Washer (2)
1/2-13 x 2” Hex
Head Bolt
Fender
Washer