Maintenance
Up/Down System
Maintenance
60HD-Rdoc072619
5-21
5
See Figure 5-12.
4.
Loosen (do NOT remove) the four lower mounting bolts to allow the bracket to move
along the slotted mounting holes.
5.
Turn the tension bolt counterclockwise to remove tension from the up/down system. Turn
the bolt until it disengages from the mounting plate assembly.
6.
Remove the four lower mounting bolts and lift the mounting plate to access the up/down
chain. Disassemble the master link securing the chain to the saw head.
FIG. 5-12
600188B
Loosen Lower Mounting Bolts (4)
Turn Tension Bolt
Counterclockwise to
Remove Tension