Sawmill Operation
Diagnostics
4
4-21
60HD-Rdoc072619
Sawmill Operation
Diagnostics
The Diagnostics menu allows you to check the software revisions, blade guide arm,
debarker in/out motor currents (amperage), and the condition of the potentiometer. It can
also be used to calibrate and troubleshoot the joystick controls. To enter the Diagnostics
menu, select Diagnostics from the User Configuration menu. Use the LEFT/RIGHT
arrows at the bottom of the display to switch the screens. Push the EXIT buttons to exit.
See Figure 4-17.
To test the movements of the joysticks and to recalibrate their center
positions, go to diagnostic screen #3 (see below). Move joysticks along both axis for diag-
nostic feedback. To recalibrate, make sure joysticks are in the center position and press
the calibration button as shown below.
Error Log
The Error Log allows you to see any errors that occurred during sawmill operation. This
information can be used to diagnose and correct the problem. To display the Error Log
screen, select the Error Log option from the User Configuration menu.
for
error code definitions.
FIG. 4-17
600337-7
Diagnostics
Diagnostics (con’t)
Diagnostics (con’t)
Diagnostics (con’t)
ECM Software Revision: 0.1.0.62rc
Debarker In/Out (A): 0.00
MCM Software Revision: 0.0.0.42rc
HMI Voltage: 11.25
Potentiometer: (_ _ _ _ _ _ _*_ _ _ _ _ _ _)
MCM Voltage: 12.12
LH Joystick
LH Joystick
HCM Voltage: 12.07
RH Joystick
RH Joystick
HCM Software Revision: 0.0.0.13rc
HMI Software Revision: 0.1.1.90rc
Blade Guide Arm (A): 0.00
Press to calibrate center
position of joysticks
Press joystick buttons and switches
to check if they work correctly
For diagnostic feedback,
use proper controls to actuate functions
1
2
3
4