81
5.10.2
SHUTDOWN VIA TIMER
If the operator cannot be present at the end of daily operation,
the machine can be disconnected via a timer.
The machine can be programmed with a maximum of 3 start-
up and shutdown times. The times correspond to weekdays
rather than dates.
For programming see:
6.1.2
EINSTELLEN EIN-/AUSSCHALTZEITEN
Note:
At the time of shutdown, stored coffee will be automatically
drained.
6
PROGRAMMING
The state-of-the-art operation of the WMF PROGRAMAT 4
as well as the simple, user-friendly display allows for easy
programming of various parameters.
For programming use the following keys:
ENTER
To enter a particular mode, press the
“ENTER“
key.
EXIT
To exit a particular mode, press the
“EXIT“
key.
To remove within a mode, press
keys.
To change standard selections use the
keys.
The new selection flashes.
To start programming turn key switch to position
“E“
.
The display indicates:
Position
“E“
(programming)
Calibration Mode
[ Info / < ] / ENTER
By pressing the key, the following information appears on
the display:
96°C Nx. Maint. 07.00
Nx. Delim.: 0033/12500
Explanation:
Boiler temp. 96°C/next maintenance July 2000, next
descaling after 12,500 litres of coffee, 33 ltr. already brewed.