73
5.2.2
START-UP VIA TIMER
Position
“T“
(timer activated)
The timer function permits automatic machine start-up. The
operator may program 3 start-up and shutdown times per day.
The times correspond to weekdays not to dates.
For programming see:
6.1.2
PROGRAMMING START-UP
AND SHUTDOWN
5.3
SELECTION OF STORED COFFEE QUANTITY
The brewing facility of the WMF PROGRAMAT 4 allows
the preparation of brewing quantities (= charges) varying
from 1, 2 or 4 litres of coffee.
Those quantities can be preselected as follows:
5.3.1
MANUAL SELECTION OF BREWING CHARGES
Usage:
Position
“W“
(“ON“ with selection options)
After warm-up phase, the display indicates:
Sel: 0L 8:17 W
Actl: 0.0L 10.01
The preselection is
0
litres
(Selection: 0L):
there will be no
automatic brewing – remaining coffee may be dispensed
completely.
To change the preselection, press the key:
Selection: 1-2L,
as soon as the stored quantity drops below
0.7 litres, the machine automatically brews 1 additional litre.
Sel: 1-2L 8:17 W
Actl: 0.0L 10.01
Selection: 1-3L,
as soon as the stored quantity drops below
1 litres, the machine automatically brews 2 additional litres.
Sel: 1-3L 8:17 W
Actl: 0.0L 10.01
Selection: 2-4L,
as soon as the stored quantity drops below
2 litres, the machine automatically brews 2 additional litres.
Sel: 2-4L 8:17 W
Actl: 0.0L 10.01
Selection: 4-8L,
as soon as the stored quantity drops below
4 litres, the machine automatically brews 4 additional litres.
Sel: 4-8L 8:17 W
Actl: 0.0L 10.01
Constantly changing, unpredictable coffee
output
Output
Time
8.00 am
12.00 pm
4.00 pm