24
If you uncheck Used on, Beep, Blink Message will be unchecked automatically. Only when you check
Used on, you can
set Beep, Blink Message function.
Click (
) Inspection Time frame to set inspection time.
Click Check by frame to select inspection interval.
Last Check Time: show the time of the last inspection.
Click (
)
▲, ▼ direction buttons on the right-hand side of Temperature frame to adjust to maximum temperature for the
HDD used in DVR. In general, it is
55
℃
.
Click (
)
▲, ▼ direction buttons on the right-hand side of HDD Damage frame to set the permissible level of HDD damage
(%). HDD is a very crucial element for DVR recording, so set the permissible level within 1% to 2% to assure maximum
safety.
While pressing (+) or (-) button on the rightmost side of Temperature or HDD Damage item, a target value increases or
decreases by 10 units.
C
hoose ‗OK‘ to confirm the setting.
4.2.3
Account
Please click (
) SYSTEM>Account, and the following screen will appear.
Please click (
) New Group, and the following screen will appear.
Click (
) keyboard icon on the right-hand side of Group Name frame. Then, the virtual keyboard will show. Please click (
)
desired characters (up to 20) on the virtual keyboard.
Do provisioning for Group Name by selectively checking
some of the following items (Setup, Search, Network, Archiving,
and Shut Down).
C
hoose ‗OK‘ to confirm the setting.
Please click (
) Login Settings, and the following screen will appear.
Selectively enable password protection for important operations (Setup, Search, Network, Archiving, and Shut Down).
Please check
the operations you wish to enable password protection.
CAUTION
YOU WILL NOT BE ASKED TO ENTER YOUR PASSWORD FOR OPERATION(S) WHERE PASSWORD PROTECTION IS NOT
ENABLED.
Login Settings
New Group