15
2.
For the Installer
2.3.6 Installing the flue gas blower, air control and lambda sensor
– Screw the flue gas blower to the blower housing with 4 wing nuts – Fig. 16.
– Hook in the air control at the top and secure with screw at the bottom – Fig. 14, 16.
– Screw the lambda sensor in finger tight and tighten approx. 1/4 turn with an open-ended wrench (SW 22) –
Fig. 15, 16.
Fig. 14 Hooking in air control at top and
screwing on at bottom
Fig. 15 Lambda sensor installed
2.3.7 Installing the lighting door with automatic ignition
– Only for LogWIN with automatic ignition (accessories) see separate installation instructions (included).
Fig. 16 Flue gas blower, air control and
lambda sensor installed
Fig. 17 Automatic ignition
Fig. 18 Lighting door with automatic ignition
Flue gas blower
Air control
Lambda sensor