For the Installer
2.3.15 Installing the mains connection and sensor
– Route the mains cable and sensor lines in the right cable channel toward the back – Fig. 40. Plug the flue gas
sensor (accessories) in the control panel to Plug X11 and also route it in the right cable channel toward the
back. Route all sensor lines through the feed-through in the cable channel downward.
– Screw the power socket to the rear of the side panel with two 2.9x16 self-tapping screws – Fig. 41.
Insert boiler sensor and safety temperature limiter sensor (STB) as far as possible into the immersion sleeve and
secure them with the sensor guard to prevent them from slipping out – Fig. 41.
– Install the flue gas sensor with protective tube (accessories) into the flue outlet as described in the installation
instructions – Fig. 41.
– Route both cables for the flue gas blower in the cable channel stoward the back – Fig. 41.
Fig. 40 Control panel, cable routing
Cable with
power plug
Boiler sensor and
STB sensor
Cable from flue gas blower
Flue gas sensor
(accessories)
Plug X11
Fig. 41 LogWIN Klassik – rear side
Power socket
Boiler sensor
STB sensor
Sensor guard
Exhaust gas sensor
with protective tube
(accessories)
Cable from flue gas blower
Cable from lambda sensor