background image

2

60706-211/J

TABLE OF CONTENTS

SAVE THESE INSTRUCTIONS 

2

SAFETY 3

SPECIFICATIONS 4

GENERATOR
ENGINE

INTRODUCTION 5

TESTING POLICY
PRODUCT DESCRIPTION

PREPARING THE UNIT 

6

UNPACKING

INSTALLATION 7

GENERATOR CLEARANCES
ENGINE-GENERATOR SET MOUNTING
FUEL INSTALLATION
LIQUID PROPANE VAPOR (LP)
NATURAL GAS (NG)
FUEL PRESSURE
FUEL PRESSURE TABLES
NG/LP FUEL CONVERSION
LUBRICATION
OIL RECOMMENDATIONS
OIL ALERT SYSTEM

INSTALLING THE BATTERY 

11

SERVICING BATTERIES
BATTERY CHARGING
BATTERY CHARGER
SOLAR CHARGER OPTION

AC ELECTRICAL CONNECTIONS 

13

GENERATOR CONNECTIONS
WINCO UL ATS (ASCO 185)

DC ELECTRICAL INTERCONNECTION  14

ASCO 185 UL SWITCH

INITIAL START UP 

15

START UP PROCEDURE
CUSTOMER CONNECTION AREA

SEQUENCE OF OPERATION 

18

DSE 3110 

19

FRONT PANEL CONFIGURATION
ACCESSING THE FRONT PANEL
EDITING A PARAMETER
DSE 3110 FAULT CODES
DSE 3110 ENGINE CONTROL
MODULE DISPLAY

PREVENTATIVE MAINTENANCE 

21

AUTOMATIC TRANSFER SWITCH
ENGINE-GENERATOR SET
ENGINE MAINTENANCE
MAINTENANCE SCHEDULE

TROUBLESHOOTING 22

OUTLINE DRAWING 

23

PAD LAYOUT DRAWING 

24

AC WIRING SCHEMATIC 

24

AC AND DC GENERATOR SCHEMATIC 25

SOLAR CONTROL PANEL 

26

EXTERNAL RECEPTACLE ASSEMBLY  26

SOLAR PANEL ASSEMBLY 

27

24 MONTH LIMITED WARRANTY 

28

LIMITED WARRANTY 

28

SAVE THESE INSTRUCTIONS

This manual contains important instructions that should 

be followed during installation and maintenance of the 

generator. Read and understand all instructions in the 

manual before starting and operating the generator.

USING THIS MANUAL

Congratulations on your choice of a WINCO generator. 

You have selected a high-quality, precision-engineered 

generator designed and tested to give you years of 

satisfactory service.

To get the best performance from your new generator, it is 

important that you carefully read and follow the operating 

instructions in this manual.

Should you experience a problem please follow the 

“Troubleshooting Tables” near the end of this manual. 

The warranty listed in the manual describes what you can 

expect from WINCO should you need service assistance in 

the future.

Summary of Contents for PSS8B2F

Page 1: ...o contact us concerning this unit it will help us to respond to your needs faster MODEL _________________________________________________ SERIAL NUMBER _________________________________________ PURCHA...

Page 2: ...WITCH ENGINE GENERATOR SET ENGINE MAINTENANCE MAINTENANCE SCHEDULE TROUBLESHOOTING 22 OUTLINE DRAWING 23 PAD LAYOUT DRAWING 24 AC WIRING SCHEMATIC 24 AC AND DC GENERATOR SCHEMATIC 25 SOLAR CONTROL PAN...

Page 3: ...t must be mixed with fresh air A Operate only in well ventilated areas B Never operate indoors including attached garages C Never operate the unit in such a way as to allow exhaust gases to seep back...

Page 4: ...er option derate 30 and note the circuit breaker derates to 25 Amp FUEL CONSUMPTION Natural Gas 1000 BTU FT LP Vapor 2520 BTU FT CF HR 132 63 BTU HR 132 000 158 760 GAL HR N A 1 6 Based on full load o...

Page 5: ...ment The ATS also contains the power failure sensing circuitry necessary to start and stop the engine generator set The transfer switch is also equipped standard with a 3 second start delay and a 15 s...

Page 6: ...crankcase the first time use the dipstick A in following image to ensure that you do not over fill the crankcase The full oil level mark on the dipstick is depicted in the following image as B Oil is...

Page 7: ...satisfactory system installation The information in this manual is offered only as a guide to finalizing your installation plans WARNING PERSONAL INJURY The enclosures on these units can become very...

Page 8: ...rimary to the low pressure regulator Consult your local fuel supplier for your exact requirements The appropriate line size from the following table is then installed from the low pressure regulator t...

Page 9: ...Natural gas Ref 2 3 4 Unit off Line PSI 7 11 in 4 6 oz 7 11 in 4 6 oz Starting Line PSI 7 11 in 4 6 oz 7 11 in 4 6 oz No load Line PSI 7 11 in 4 6 oz 7 11 in 4 6 oz Full load Line PSI 7 11 in 4 6 oz...

Page 10: ...sh off immediately with water 3 If electrolyte contacts the eyes flush immediately and thoroughly with water Seek immediate medical attention 4 Spilled electrolyte is to be washed down with an acid ne...

Page 11: ...be fused for 15 Amps Terminal block connections have been provided in the customer connection area of the engine generator set See following diagram NOTICE The battery tender is not intended to recha...

Page 12: ...als L3 L7 The neutral leads from all three locations are connected to the isolated terminal lugs on the sidewall of the cabinet This terminal block is labeled NEUTRAL and the terminal lugs are mounted...

Page 13: ...through 9 These terminals will accept 22 14 AWG stranded wire It is recommended that you use 16 AWG for distances up to 200 feet You need to run two 2 wires from the engine generator set to the transf...

Page 14: ...y Deep Sea Electronics Model 3110 is used on this generator set See following picture and look for more information stated within this manual MANUAL OPERATION Press and release the red Stop Reset butt...

Page 15: ...hanging the exercise without a load will be discussed later Be sure that conditions are safe to do this operation BYPASS TIME DELAY Use this button to cancel the active time delay or exercise period s...

Page 16: ...art and run the exerciser must be reset after the power is restored The ASCO 185 has settings that can be changed for various applications The dipswitch options are explained in the ASCO 185 Operator...

Page 17: ...17 60706 211 J SEQUENCE OF OPERATION UTILITY FAILURE...

Page 18: ...Auxiliary inputs can be user configured and will display he message as written by the user Fail to Start The engine has not fired after the preset number of start attempts Fail to Stop The module has...

Page 19: ...The fault must be removed and the Stop Reset button pressed to reset the module The icon will appear flashing in the display MODULE DISPLAY TIMER ICON When the module is controlling the engine startin...

Page 20: ...il level must always be checked before the engine is started Refer to page 7 of this manual for instructions on checking the oil level Take care to remove any dirt or debris from around the oil plug b...

Page 21: ...ked up engine generator set 9 Defective starter fuel solenoid relays ENGINE CRANKS BUT WILL NOT START 1 Improper fuel pressure being delivered to unit 2 Fuel supply shut off 3 Fuel supply empty 4 Defe...

Page 22: ...22 60706 211 J 36 50 28 00 29 75 36 00 27 375 28 375 OUTLINE DRAWING...

Page 23: ...23 60706 211 J PAD LAYOUT DRAWING 11075 00 20 60706 211 ENGINE GENERATOR SET PAD LAYOUT...

Page 24: ...24 60706 211 J AC WIRING SCHEMATIC...

Page 25: ...25 60706 211 J 11075 00 22 60706 211 AC AND DC GENERATOR SCHEMATIC AC AND DC GENERATOR SCHEMATIC...

Page 26: ...26 60706 211 J EXTERNAL RECEPTACLE ASSEMBLY IF EQUIPPED SOLAR CONTROL PANEL IF EQUIPPED...

Page 27: ...27 60706 211 J SOLAR PANEL ASSEMBLY IF EQUIPPED...

Page 28: ...does not cover travel time mileage or labor for removal or re installation of WINCO product from its application Normal wear and tear Costs of rental equipment WINCO does not warrant engines Engines a...