1 General

1.1 About this document

These Installation and Operating Instructions form 
an integral part of the unit. They must be kept close 
to the unit and in readiness whenever required. Pre-
cise observance of these instructions is a pre-condi-
tion for use of the unit for the intended purpose and 
for its correct operation.
These Installation and Operating Instructions con-
form to the relevant version of the equipment and 
the underlying safety standards valid at the time of 
going to press.

2 Safety

These instructions contain important information 
which must be followed when installing and operat-
ing the pump. It is therefore imperative that they be 
read by both the installer and the operator before 
the pump is installed or started up.
Both the general safety instructions in the ‘Safety 
precautions’ section and those in subsequent sec-
tions indicated by danger symbols should be care-
fully observed.

2.1 Symbols and signal words used in these operating 

instructions

Symbols:

NOTE:...

Signal words:

NOTE:
A NOTICE WITH USEFUL INFORMATION FOR THE 
USER IN RELATION TO THE PRODUCT. IT INFORMS 
THE USER TO POSSIBLE PROBLEMS.

2.2 Qualified Personnel

The personnel installing the pump must have the 
appropriate qualifications for this work.

2.3 Risks incurred by failure to comply with the safety 

precautions

Failure to comply with the safety precautions could 
result in personal injury or damage to the pump or 
installation. Failure to comply with the safety pre-
cautions could invalidate warranty and/or damage 
claims.
In particular, failure to comply with these safety pre-
cautions could increase the possibility of the follow-
ing risks:

• the failure of important parts of the pump or instal-

lation,

• personal injury due to electrical and mechanical 

causes,

• material damage.

2.4 Safety precautions for the operator

Existing regulations for the prevention of accidents 
must be observed.
National Electrical Codes, local codes and regula-
tions must be followed.

2.5 Safety precautions for inspection and installation

The operator must ensure that all inspection and 
installation work is carried out by authorized and 
qualified specialists who have carefully reviewed 
these instructions. 
Work on the pump/unit must be carried out only with 
the pump switched off and at complete standstill.

2.6 Unauthorized alterations and manufacture of 

spare parts

Alterations to the pump or installation may only be 
carried out with the manufacturer's consent. The use 
of original spare parts and accessories authorized by 
the manufacturer will ensure safety. The use of any 
other parts may invalidate claims invoking the liabil-
ity of the manufacturer for any consequences.

2.7 Improper use

The operational safety of the pump or installation 
supplied can only be guaranteed if it is used in accor-
dance with paragraph 4 of the operating instruc-
tions. The limits given in the catalogue or data sheet 
must under no circumstances be exceeded.

General Safety symbol

Hazards from electrical causes

DANGER!
Imminently hazardous situation.
Will result in death or serious injury if not avoided.

WARNING!
The user can be exposed to (severe) injury. 'Warn-
ing' refers that harm to the user when the user is 
neglecting the procedure.

CAUTION!
The product is at risk of damage. 'Caution' refers 
to the product when the user is neglecting the 
procedures.

Summary of Contents for MVIS 15

Page 1: ...2 065 408 03 2009 GRD Wilo MVIS 15 30 50 GB Installation and operating instructions F Notice de montage et de mise en service E Instrucciones de instalaci n y funcionamiento...

Page 2: ...Fig 1 Fig 2 R D S K U H C M A T B L P F E Fig 3 Fig 4 S1 L1 L2 L3 S2 K K K 3 P1 P2 L1 L2 L3...

Page 3: ...GB Installation and operating instructions 3 F Notice de montage et de mise en service 9 E Instrucciones de instalaci n y funcionamiento 15...

Page 4: ...aims In particular failure to comply with these safety pre cautions could increase the possibility of the follow ing risks the failure of important parts of the pump or instal lation personal injury d...

Page 5: ...d any outside influences humidity frost etc CAUTION Possible damage of the pump These pumps are intended for use with water only Example MVIS15 02 1 O K 3 460 60 2 MVIS Pump family 15 Nominal flow rat...

Page 6: ...hook or a ring of sufficient capacity total weight of pump to allow the use of a hoist or similar device for the servicing and repair of the pump When fitting the oval flange only the screws sup plied...

Page 7: ...ed liquid flows The escaping air produces a clearly audible whistle Retighten the air bleed screw Slowly open the isolation valve on the discharge side The gauge on the discharge side is used to monit...

Page 8: ...if there is no risk of frost If the place of installation is not protected from frost the pumps and pipes must be emptied for the winter Close the isolation valves open the discharge screws at the bas...

Page 9: ...S BUT PROVIDES IN SUFFICIENT FLOW AND OR PRES SURE a Wrong direction of rotation a Check the direction of rotation of the motor and correct it if necessary b Pipe obstructed by foreign material b Chec...

Page 10: ...accro tre la probabilit des risques suivants d faillance de fonctions importantes de la pompe ou de l installation dangers pour les personnes par influences lectrique ou m canique dommages mat riels 2...

Page 11: ...s impacts et de toutes influences ext rieures humidit gel etc ATTENTION Risque d endommager la pompe Ces pompes conviennent uniquement au refoulement de l eau Exemple MVIS15 02 1 O K 3 460 60 2 MVIS F...

Page 12: ...et plane Toute inclinaison de la pompe provoque l usure pr matur e du palier Installer la pompe sur un massif mini 10 cm 4 de haut Pr voir un mat riaux isolant li ge ou caout choux arm sous la pompe...

Page 13: ...tiquette de la pompe Le c ble de raccordement doit tre plac de fa on ne jamais entrer en contact avec la canalisation prin cipale et ou le corps de pompe et la carcasse moteur La pompe installation do...

Page 14: ...r FIG 3 rep 6 et la vis AVERTISSEMENT Blessure corporelle Pompe sous pression Lorsque l on travaille avec des temp ratures de liquides refoul s lev es et des pressions importantes le jet s chappant de...

Page 15: ...10 2 La pompe fonctionne mais ne refoule pas sufisamment a Sens de rotation incorrect a V rifier le sens de rotation du moteur et l inverser au besoin b La conduite est obstru e par des corps tranger...

Page 16: ...de mante nimiento y reparaci n Lesiones personales debidas a causas el ctricas mec nicas o bacteriol gicas Da os materiales 2 4 Instrucciones de seguridad para el operador Deber n cumplirse las norma...

Page 17: ...factores externos humedad heladas etc Atenci n Riesgo de da ar la bomba Estas bombas s lo son tiles para la conexi n de salida del agua Ejemplo MVIS15 02 1 O K 3 460 60 2 MVIS Familia de bomba 15 Caud...

Page 18: ...ca el desgaste con mayor rapidez del cojinete Instale la bomba sobre un masivo m nimo 10 cm 4 de altura Prevea un material aislante corcho o cau cho armado bajo la bomba para evitar las molestias sono...

Page 19: ...entre en contacto con la canalizaci n principal y o con el cuerpo de la bomba y la carcasa del motor La bomba instalaci n debe estar conectada a tierra siguiendo las regulaciones locales Un interrupto...

Page 20: ...abajamos con temperaturas de l quidos de impulsi n muy altas y con presiones importantes los chorros que se escapan del tornillo de la purga de aire pueden ocasionar quemaduras y heridas Por este moti...

Page 21: ...ombas y los con ductos durante el invierno Cierre las v lvulas de corte abra las v lvulas de drenaje en el pie de la bomba Ver FIG 3 rep 6 y el tornillo de purga de aire Ver FIG 3 rep 5 Es imprescindi...

Page 22: ...pero no tiene suficiente presi n a Sentido de rotaci n incorrecto a Compruebe el sentido de rotaci n e invi rtalo si es necesario b El conducto se encuentra obstruido por cuerpos extra os b Controle...

Page 23: ...SA Phone 866 945 6872 WILO USA FAX 708 338 9455 WILO EMU LLC 86 Genesis Parkway Thomasville Georgia 31792 USA Phone 229 584 0097 FAX 229 584 0234 WILO Canada Inc Bay 7 2915 10th Ave N E Calgary Albert...