• Only transport the product on the pallet and
only use approved handling equipment.
• Make sure the product is stable in transit.
• Prior to installation, store the product on the
pallet so that it remains dry and is protected
from the sun.
4 Use as intended
The Wilo DrainLift WS625 is used in combination
with a submersible pump as a pump station for
domestic sewage that is both free of faeces and
contains faeces in accordance with EN 12056-1. It
is used to drain drainage points in buildings and on
sites below the backflow level, where sewage
cannot drain into the public drains with a natural
gradient.
WARNING! Health hazard!
Because of the materials used, this product is
not suitable for supplying drinking water! Con-
taminated sewage is a health hazard. Do not use
the pump station inside buildings.
CAUTION! Risk of damage!
The introduction of inadmissible substances
into the drains can cause damage to the product.
Never introduce solids, fibrous substances, tar,
sand, cement, ash, coarse paper, debris, rubbish,
animal waste, grease, oil or swimming pool
water into the drains!
Use of the product as intended also means follow-
ing these instructions.
Use over and beyond the use described is not use
as intended.
5 Product information
5.1
Type code
5.3
Dimensions
The main dimensions are shown in mm on the
dimension drawing (Fig. 1) - for further informa-
tion, see data sheet/catalogue
5.4
Scope of supply
• Wilo DrainLift WS625>, consisting of the
components (Fig. 2):
1
plastic shaft
2
internal pipework
2a pressure outlet
2b gate valve
2c pipe screw connection
3
inflow connection with seal
4
connection for ventilation/cable duct with
seal
5
chain hooks
• Installation and operating instructions
NOTE:
If it is to be used as a pump station, accessories are
needed that have to be ordered separately (see
Accessories).
Example: WS 625 E / 1500
WS
Series:
W
ilo shaft pump station
S
ynthetic
625
Pump shaft diameter [mm]
E
E = Individual pump
1500
Shaft height [mm]
5.2
Technical data
Note:
max. admissible pressure in the
6 bar
in combination with pump MTS 40
pressure pipe:
4 bar
in combination with pumps TMW32, TC40
Pressure pipe connection
DN40
PE pipe, connection via clamp bolting
Inflow connection
DN 100
Ventilation connection / cable bushing
DN 100
max. admissible ambient temperature:
20°C
ground, below depth of 0.5 m
max. admissible groundwater level:
800 mm
above bottom of shaft, permanent
to top of shaft
max. 1 week
Storage volume
see data sheet/catalogue
Suitable pump types
see data sheet/catalogue
Suitable Wilo shaft cover
see catalogue/see Accessories
Note application according to EN 124!
Type
H [mm]
A [mm]
WS 625 E / 1200
1260
-
WS 625 E / 1500
1560
900
WS 625 E / 1800
1860
1200
WS 625 E / 2100
2160
1800
Summary of Contents for DrainLift WS625
Page 3: ...Fig 2 H X Y 2 2a 10 5 4 3 1a 1 11 6...
Page 4: ...Fig 3 Fig 4 E 3 4 3 1 2 3 Fig 5 Fig 6 B 5 1 3 4 2 2 6 1 Fig 7 Fig 8 3 2 1 3 2 1...
Page 6: ......
Page 48: ...Svenska 44 Wilo AG 05 2005...
Page 79: ...Wilo DrainLift WS625 75 1 1 1 2 2 1 2 2 2 3 2 4 2 5 2 6 2 7 4...
Page 84: ...80 Wilo AG 05 2005 3 7 2 8 9 EN12056 4 Wilo 10 Wilo Wilo 11 Wilo...