15
4 Mounting
WIKA Operating Instructions - Differential pressure transmitter DPT-10
+ –
2
1
Fig. 10: Marking for plus/minus side on the process component
1 Plus side
2 Minus side
The following illustration shows the elements for a tube mounting and
an example for a mounting arrangement with valve block.
2 3 4
5
6
7
8
9
10
1
Fig. 11: Mounting arrangement with tube mounting
1 Strap for tube mounting
2 Mounting bracket
3 Ventilation valve
4 Fixing screws
5 DPT10
6 PTFE seal
7 Valve block
8 Oval flange adapter
9 Fixing screws
10 Effective pressure line
Valve blocks enable the simple installation and setup of the differential
pressure transmitter. They separate the pressure transmitter from the
process side and enable also a check of the measurement loop. They
Mounting arrangement
Valve blocks