Kunststoffschweißtechnik
Operating
and
indicating elements
Chapter 4
25.03.14
Working Instructions WIDOS ASM 315 WM
Page 16 of 45
4.2. Heating element and control
No. Denomination
Function
10 On / off switch red
illuminated
- as soon as the heating element is switched on, it is
heated up.
11 Temperature
regulator
- to set and control heating temperature
12 10-pole power socket with
cap + safety bracket
- Connection to the heating element, plug should always
be retained by the safety bracket
13 cable with plug 10-pole
- Connection to control
14 Connecting cable
- Connection with power supply 230 V / 16 A / 50 Hz
15 Bolt
- holder for heating element
16 Heating area
- to heat up the main pipe and branch pipe
17 Grip on heating element
- to transport the heating element
- to move the heating area
4.2.1. How to set the heating element temperature
Display = Display of the actual value
Push shortly the button P (1), the display shows <SP>,
change desired value with buttons
▲
(3)
▼
(2).
Push shortly the button P (1), actual temperature is
displayed again (or automatic change after 30s).
During heating up to desired value, the control lamp K2 (4)
is on, having reached the desired temperature, the control
lamp K2 (4) is blinking.
11
12
14
10
15
16
17
13