Operating and indicating elements
Chapter 4
23.06.2015
Working instructions WIDOS 5000 WM
Page 22 of 80
4.5.
Switch cabinet
No.
Denomination / Function
35
Temperature regulator for heating element
36
2 x lock for electrical cabinet
The key is only to be handed over to authorized personnel!
37
Main switch, for switching the machine on / off
38
Mains connecting cable 400 V / 32 A
QA2
Emergency stop contactor
FC2
Circuit breaker K8A, control fuse
FC10
Motor protection switch 2,8 – 4A; hydraulic - pump
FC20
(3 pcs.) Circuit breaker B 16 A; heating element
FC40
Motor protection switch 2,8 – 4,0 A; planer
TB1
Switching power supply 24 V
QA10
Hydraulic pump contactor
QA20 Heating
element
contactor
QA40 Planer
contactor
35
37
38
FC20 I FC2 I QA2 I FKZ I F30 I T1
36
QA10 I QA20 I QA40