Foundation: 2207, 2208 DIN 16932 German association for welding
Use for:
5000 WM / 5002 WM (with 2. cylinder)
1 bar on manometer:
94 N
time to
change-
reach full
over
welding
cool-down time
0,10 (PP)
time
pressure
pressure in
T
desired
temperature
time
The following pressure values are only valid if the 2. cylinder is used.
pipe
pipe
SDR
bead-up
circular
heat-up
max.
time
welding
cool-
diameter
wall
pressure
bead
time
change-
to reach
pressure
down
OD
(s)
[bar]
min.
[s]
over
welding
[bar]
time
[mm]
[mm]
[mm]
time
pressure
[min]
[s]
[s]
160
4,0
41
3
0,5
126
5
6
3
5
160
4,9
33
3
0,5
141
5
6
3
7
160
6,2
26
4
0,5
162
6
7
4
10
160
9,1
17,6
5
1,0
204
6
9
5
15
160
14,6
11
8
1,0
277
8
13
8
24
160
21,9
7,4
11
1,5
359
10
19
11
34
160
26,6
6
12
2,0
405
11
23
12
41
180
4,4
41
3
0,5
133
5
6
3
6
180
5,5
33
4
0,5
151
5
6
4
8
180
6,9
26
4
0,5
173
6
7
4
12
180
10,2
17,6
6
1,0
220
7
10
6
17
180
16,4
11
9
1,0
298
8
15
9
26
180
24,6
7,4
13
1,5
386
11
21
13
38
180
29,0
6
15
2,0
423
12
25
15
44
200
4,9
41
4
0,5
141
5
6
4
7
200
6,2
33
5
0,5
162
6
7
5
10
200
7,7
26
5
1,0
185
6
8
5
13
200
11,4
17,6
8
1,0
237
7
11
8
19
200
18,2
11
12
1,0
320
9
16
12
29
200
27,4
7,4
16
2,0
411
11
23
16
42
200
33,2
6
19
2,0
456
13
29
19
50
Table for PP
Additional to the given bead-up force and to the welding force the moving force of the support must be added !
The standard value for heating element temperature is 210° C +/- 10° C.
welding area
in welding area
The smaller the pipe wall the higher the temperature.
P (N/mm²)
bead-up
heat-up
23.06.2015
Working instructions WIDOS 5000 WM / 5002 WM with 2
nd
cylinder
Page 40 / 1 of 80