Operating and indicating elements
Chapter 4
23.06.2015
Working instructions WIDOS 5000 WM
Page 19 of 80
Always disconnect the hydraulic hoses of the additional cylinder from the hydraulic unit if the
cylinder is placed onto the holder on the right side.
In case you disconnect the hoses of the additional cylinder from the machine you are not to
move the tables since the additional cylinder cannot move along.
In case you have driven the machine without connected additional cylinder, then plug the
additional cylinder to the distributor block, drive the tables and the additional cylinder entirely
apart and mount the additional cylinder onto the clamping tools only afterwards.
4.2.
Elements on the operating panel
No.
Denomination / Function
20
Pressure relief valve, adjust the table pressure (read value from pressure gauge)
21
Stop watch, magnetic (option)
22
Pressure gauge – pressure indication [0 – 250 bar]
23
Emergency - stop – switch,
24*
Button: <heater out>, open up heating element and drive it out of machine
25*
Sensor: <heater in>, open up heating element and drive it into machine
24
Switch – <limitation> on (1): control lamp illuminates / off (0): control lamp extinguishes
25
Control lever for tables: <Backwards> / <Forwards> / <Pressure release>
26
Switch – <planer> on (1) / off (0)
27*
Sensor <Planer out>, drive planer out of machine
28*
Sensor – <Planer in> drive planer into machine
* Please keep buttons pressed until the tools have reached their final position.