Foundation: 2207, 2208 DIN 16932 German association for welding
Use for:
5000 WM / 5002 WM (with 2. cylinder)
1 bar on manometer:
94 N
time to
change-
reach full
over
welding
cool-down time
0,10 (PP)
time
pressure
pressure in
T
desired
temperature
time
The following pressure values are only valid if the 2. cylinder is used.
pipe
pipe
SDR
bead-up
circular
heat-up
max.
time
welding
cool-
diameter
wall
pressure
bead
time
change-
to reach
pressure
down
OD
(s)
[bar]
min.
[s]
over
welding
[bar]
time
[mm]
[mm]
[mm]
time
pressure
[min]
[s]
[s]
Table for PP
Additional to the given bead-up force and to the welding force the moving force of the support must be added !
The standard value for heating element temperature is 210° C +/- 10° C.
welding area
in welding area
The smaller the pipe wall the higher the temperature.
P (N/mm²)
bead-up
heat-up
225
5,5
41
5
0,5
151
5
6
5
8
225
6,9
33
6
0,5
173
6
7
6
12
225
8,6
26
7
1,0
197
6
8
7
15
225
12,8
17,6
10
1,0
255
7
12
10
21
225
20,5
11
15
1,5
345
9
18
15
32
225
30,8
7,4
20
2,0
437
12
26
20
47
225
37,4
6
24
2,5
487
14
32
24
55
250
6,2
41
6
0,5
162
6
7
6
10
250
7,7
33
7
1,0
185
6
8
7
13
250
9,6
26
8
1,0
211
7
9
8
16
250
14,2
17,6
12
1,0
272
8
13
12
23
250
22,7
11
18
1,5
367
10
20
18
35
250
34,2
7,4
25
2,0
463
13
29
25
51
280
6,9
41
7
0,5
173
6
7
7
12
280
8,6
33
8
1,0
197
6
8
8
15
280
10,7
26
10
1,0
227
7
10
10
18
280
15,9
17,6
15
1,0
292
8
14
15
26
280
25,4
11
22
1,5
394
11
22
22
39
280
38,3
7,4
31
2,5
493
14
33
31
57
315
7,7
41
8
1,0
185
6
8
8
13
315
9,7
33
10
1,0
213
7
9
10
16
315
12,1
26
13
1,0
246
7
11
13
20
315
17,9
17,6
18
1,0
317
9
16
18
28
315
28,6
11
28
2,0
420
12
24
28
44
23.06.2015
Working instructions WIDOS 5000 WM / 5002 WM with 2
nd
cylinder
Page 40 / 2 of 80