Operating and indicating elements
Chapter 4
23.06.2015
Working instructions WIDOS 5000 WM
Page 23 of 80
4.5.1.
Main switch
You activate and shut down the machine by the main switch.
Shut down the machine and secure switch against unintentional
activation while working within the machine.
4.6.
How to clamp pipes of 15° (optional)
The 15° clamping tools are each screwed to the
machine table on the front and rear by a clamping claw.
The pipes are clamped with spindle pressure disc and clamping nut, for this purpose swivel in or out the
released spindle (arrow).
4.6.1.
How to install the reducer inserts (optional)
The optional reducer inserts must be flushed with the machine
center.
Open up the clamping tools.
The lower reducer inserts are installed at first.
Afterwards put the upper reducer inserts onto the lower ones, shut
the clamping tool and screw reducer inserts with the clamping tool.
Denomination / Size
Connecting screw
Reduction insert OD = 450
Pan head screw M 10 x 30 DIN 912
Reduction insert OD = 400
Pan head screw M 10 x 35 DIN 912
Clamping claw
Spindle, pressure washer and clamping nut