Operating and indicating elements
Chapter 4
23.06.2015
Working instructions WIDOS 5000 WM
Page 21 of 80
4.4.
Service unit and pneumatic valves
No.
Denomination / Function
29
Pressure regulator with pressure gauge to set the working pressure
30
Manual start valve with sound absorber, to switch on / off the compressed air
31
Connection for compressed air hose (connection with local compressed air supply)
32
Manual outlet for condensating water
M9
Table stopper, for a limited opening-up during change-over
QM21
Heating element drives into machine
QM22
Heating element drives out of machine
QM31
Planer drives into machine
QM32
Planer drives out of machine
The service unit (LFR-3/8“-D-Maxi-KC), adjusts the incoming compressed air to the adjusted working
pressure and compensates fluctuations in pressure. It clears the compressed air of dirt and condensation
water. The use with any other fluid (liquid or gas) is a misapplication.
4.4.1.
How to adjust the regulator:
Slowly pressurize the complete system.
Pull the pressure setting button upwards (away from the housing).
Turn the pressure setting button until the desired pressure is shown on the manometer. The input
pressure must be at least 1 bar higher than the output pressure.
Press the pressure setting button downwards (towards the housing) to secure it against unintentional
turning.
31
32
33
34
QM9
QM22
QM21
QM32
QM31