www.whisperkool.com | Page 13
Platinum Split
°
F
°
F
18.
Remove the wire nuts from the black, white and green wires located
in the lower left corner of the Evaporator Unit.
19.
Following the supplied wiring diagram on page 18, connect the
power supply wires to the black, white and green wires using the
supplied wire nuts (Hot=Black, Neutral=White, Ground= Green).
20.
Install the supplied black strain relief to secure the power supply
wires in the housing.
21.
Route the keypad adapter through the grommet below the drip
tray and into the blower compartment.
Note: Keypad adapter is
packaged in the accessory kit, not with the evaporator .
22.
Connect the keypad adapter to the circular connector for the bottle
probe in the lower left corner of the housing.
23.
Secure all wiring neatly and as close to the left wall as possible in
order to minimize airflow obstruction.
24.
Attach the supplied bottle probe to the circular connector on the
bottom of the unit. Follow the directions on page 33 for correct
installation and placement of the bottle probe.