Page 32 | 1-800-343-9463
PS
011717
INSTALLING THE WALL MOUNT KIT
°
F
DRAIN PAN
1.
If removed, reinstall the top panel of the unit housing.
2.
Connect the red wire from the keypad adapter to the upper (+) terminal on the display located on the front grille.
3.
Connect the black wire from the keypad adapter to the lower (-) terminal on the display.
Note: Keypad adapter is packaged
with the accessory kit, not with the evaporator .
4.
Align the front grille with the four (4) ball studs on the housing. Push the front grille onto the ball studs until it snaps into
place.
5.
Using a Phillips-head screwdriver, fasten the bottom two (2) screws to fasten the grille to the unit.
INSTALLING THE DUCTED PLENUM
1.
If removed, reinstall the top panel of the unit housing.
2.
Align duct plenum with the four (4) ball studs on the housing. Push the duct plenum onto the ball studs until it snaps into
place.
3.
Using a Phillips-head screwdriver, fasten the bottom two (2) screws to fasten the plenum to the unit.
4.
Connect the supply and return duct work to the unit.
5.
Using duct tape or foil tape, seal the seam between the plenum and unit.
6.
Insulate all exposed metal on the unit to prevent surface condensation.
NOTE: A 12”x12” return air filter grille must be installed to prevent contaminants from entering the cooling system. Supply duct
must be insulated so it does not sweat or pick up heat.
NOTE: Max ducting length is 25 feet.