Page 6 | 1-800-343-9463
PS
011717
WALL-MOUNTED PLATINUM SPLIT: UNIT SPECIFICATIONS
Model
4000 Evaporator
(Fan Coil Unit)
4000 Condenser
(Air-Cooled
Condensing Unit)
8000 Evaporator
(Fan Coil Unit)
8000 Condenser
(Air-Cooled
Condensing Unit)
Cellar Size (cu. ft.)
1000
2000
Dimensions
20.5”w x 15.5”h x
16.1”d
12”w x 13.5”h x 18”d
20.5”w x 15.5”h x
16.1”d
12”w x 13.5”h x 18”d
BTUh with 90°F air enter-
ing the condenser coil
3650
4450
CFM
270
190
278
350
Refrigerant
R-134a
Condensing Unit HP
1/3++
1/2
Voltage Rating
115V (20-amp dedicated circuit required)
Weight (lbs)
56
56
56
66
AMPS
(Starting/Running)
2/1
32.7/7.2
2/1
48/9.5
dBA
54
65
54
65
Drain Line
1/2” ID clear plastic tubing
Installation
Evaporator Unit (Fan Coil Unit) is installed in the cellar or up to 25 ducted feet away.
Condensing Unit is installed up to 100 feet from Evaporator Unit (Fan Coil Unit).
Thermostat
Digital keypad
Temp. Delta
55°F temperature differential between cellar environment and Condensing Unit intake air.
Warranty
2-year parts and labor
°
F
Keypad
Filter Grille
Evaporator Unit (Fan Coil Unit)