![WhisperKool Platinum Split 4000 Evaporator Technician Manual Download Page 9](http://html.mh-extra.com/html/whisperkool/platinum-split-4000-evaporator/platinum-split-4000-evaporator_technician-manual_975284009.webp)
www.whisperkool.com | Page 7
Platinum Split
DUCTED PLATINUM SPLIT: UNIT SPECIFICATIONS
Model
4000 Evaporator
(Fan Coil Unit)
4000 Condenser
(Air-Cooled
Condensing Unit)
8000 Evaporator
(Fan Coil Unit)
8000 Condenser
(Air-Cooled
Condensing Unit)
Cellar Size (cu. ft.)
1000
2000
Dimensions
20.5”w x 15.5”h x 22.5”d 12”w x 13.5”h x 18”d
20.5”w x 15.5”h x 20”d
12”w x 13.5”h x 18”d
BTUh with 90°F air
entering the condenser
coil
3120
3788
CFM
200
190
200
350
Refrigerant
R-134a
HP
1/3++
1/2
Voltage Rating
115V (20-amp dedicated circuit required)
Weight (lbs)
57
56
57
66
AMPS
(Starting/Running)
2/1
32.7/7.2
2/1
48/9.5
dBA
54
65
54
65
Drain Line
1/2” ID clear plastic tubing
Installation
Use 8” supply and 10” return insulated ducting. Ducting should not exceed 25 feet from cellar.
Thermostat
Remote digital keypad
Temp. Delta
55°F temperature differential between cellar environment and Condensing Unit intake air.
Warranty
2-year parts and labor
°
F
Remote Keypad for Ducted Systems
Duct Plenum
Return Air
Supply Air