5-2
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
VENT CIRCuIT
DETERGENT AND RINSE
AID CIRCuIT
1. Place one probe on the P10 Pin 1 position
and the other on P10 Pin 3 position.
2. Should be between 600 Ω to 1800 Ω.
1. Place one probe on the P10 Pin 1 position
and the other on P11 Pin 10 position.
2. Should be between 280 Ω to 340 Ω.
1. Place one probe on the P10 Pin 1 position
and the other on P12 Pin 6 position.
2. Should be between 1300 Ω to 1600 Ω.
DRAIN MOTOR CIRCuIT
DIVERTER VALVE CIRCuIT
1. Place one probe on the P10 Pin 1 position
and the other on P10 Pin 6 position.
2. Should be between 15 Ω to 19 Ω.
o
Summary of Contents for Gold GU2800XTV
Page 4: ... iv NOTES ...
Page 55: ...4 15 NOTES ...
Page 68: ...6 11 SERVICE DIAGNOSTIC CYCLE CHART ...
Page 69: ...6 12 NOTES ...
Page 73: ...7 4 ...
Page 75: ...CORPORATION ...