2-14
Connect 90° elbow fitting to
water inlet valve
4
Connect 90° elbow fitting to water inlet valve.
Using a wrench, tighten elbow until snug, and
be sure that it faces to the rear.
Remove terminal box cover
5
Using a 1/4” hex head socket, nut driver or
Phillips screwdriver, remove terminal box cover.
Retain for later use.
Install conduit connector
6
Install a U.L. listed or CSA approved conduit
connector. Make sure screwheads are facing
to the left when tightening conduit nut. Conduit
connector may be provided with the power
supply cord kit.
What type of electrical
connection will you use?
Power Supply Cord:
Follow Option A instructions
Direct Wire:
Follow Option B instructions
Make Power Supply Cord
Connection
Option A, Power Supply Cord:
Power Cord—Route cord
into terminal box
1
Route cord so that it does not touch dishwasher
motor to lower part of dishwasher tub. Pull cord
through conduit connector in terminal bow.
Select UL listed or CSA approved twist-on
wire connectors (not included) rated to connect
your household wiring to 16-gauge dishwasher
wiring.