4-10
REMOVING THE SUMP
6. Open the dishwasher door.
7. Remove both dishracks.
8. Remove the upper and lower filters.
(see page 4-3 for procedure)
9. Remove the lower Spray Arm assembly.
(see page 4-2 for procedure)
10. Remove the Turbo wash manifold.
(see page 4-6 for procedure)
11. Remove the feed tube assembly.
(see page 4-6 for procedure)
12. Reach under the dishwasher and push up
on the sump to separate the seal of the
sump from the tub bottom.
13. Lift the sump from inside the dishwasher
tub and prop the front edge up so the
connections to the OWI, optical water
indicator, are accessible.
14. Disconnect the OWI wiring by lifting the lock-
ing tab and removing the wire connector.
1. Unplug dishwasher or disconnect power.
2. Remove the access panel and toe panel.
3. Remove the drain hose.
4. Remove the drain pump.
5. Reach under the dishwasher and rotate
each of the 3 sump tabs 1/4 turn clockwise
to unlock the sump from the tub.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Tab by Wash
Motor
Tab by
Drain
Pump
Tab by
Diverter
Tub
Bottom
Optical Water
Indicator Wire
Connector
Note: Do not use the upper filter tabs to
lift the pump.
Upper filter tabs
DO NOT use
these tabs to lift
pump