Parameters, Units and Ranges
Approximately following the
VP‑8
iP
’s signal path, these are the values and ranges appropriate
to each type of processing.
System Level
Headroom:
20dB
Nominal Operating Level:
-20dBFS digital
Analog Line Input
Type:
Electronic
Differential
Input Impedance:
> 10Kohm (bridging)
Optimum Source Impedance:
< 1Kohm
Digital Line Input
Data
Standard:
AES3
(AES/EBU)
Data
Amplitude:
Per
AES3-2003
assuming
minimum
allowable
output signal amplitude of 2V and minimum
allowable input signal amplitude of 200mV
Input Gain Adjustment Ranges
Gain
Adjustment: -36dB
to
+12dB
Gain
Adjustment
Increments:
0.5dB
Gain Calibration:
A gain control setting of 0.0 aligns an external
0dBFS signal with the
VP‑8
iP
’s 0dBFS
internal reference
Input Failsafe
Type:
Automatic
Analog Fail Cause:
Audio level below -48dBFS.
Response
Time:
30
seconds
Digital Fail Cause 1:
Audio level below -48dBFS
Response
Time:
30
seconds
Digital Fail Cause 2:
Corrupted or invalid AES data
Response
Time:
Immediate
Audio Level Balance
Type:
Common
to
Analog
and
Digital
inputs
Analog/Digital L/R Balance Range:
+/-12dB
Analog/Digital L/R Balance Increments: 0.5dB