page 4 – 32
VP-8IP / Sep 2013
V P - 8
i P
P R O G U I
From the AM Output Screen when in AM Mode:
DeEmphasis
Predelay
TX Tilt EQ
Digital Output
TX 1
TX 2
Analog - L/R, L/R Deemph
From the FM‑HD Output Screen when in FM‑HD Mode:
Digital Output
Analog Output
From the AM‑HD Output Screen when in AM‑HD Mode:
Digital Output
Analog Output
From the MP3/ACC>48K Output Screen when in MP3/AAC>48k Mode:
Digital Output
Analog Output
From the MP3/ACC<48K Output Screen when in MP3/AAC<48k Mode:
Digital Output
Analog Output
The option allows the
VP‑8
iP
to modify its input and output gain settings whenever
presets are recalled. Input and output gain settings are always stored with the presets
when processing values are stored, but those settings will be ignored upon preset recall
when the Input/Output Settings Change With Presets check box is unchecked.
Metering Data Over TCP/IP
The
VP‑8
iP
utilizes the UDP protocol by default
for transmitting metering data to the remote GUI
(TCP with its guaranteed packet delivery is always
used for control).
In some instances UDP packets are blocked by In-
ternet Service Providers, and when this occurs the GUI
can successfully connect to the
VP‑8
iP
but there is no
visible metering data. Unless one can successfully convince the ISP to allow unsolicited
UDP traffic on their network (doubtful) the solution is to utilize VPN Tunneling (which
encapsulates all packets into TCP) or simply switching the
VP‑8
iP
and its GUI to using
the TCP protocol for metering.
Switching the
VP‑8
iP
to utilize TCP instead of UDP is done through the System menu.
In the upper left corner of that screen is a check box Metering data over TCP/IP. When
the box is checked the TCP protocol is used for transmitting metering data instead of UDP.