33
The telemetry interface displays the collected
telemetry data.
Note:
Inhibiting "Telemetry" when link will affect the use
of [Range Check] [Low Battery] [W.BUS Servo]
[Telemetry].
Shutdown protection system:
When the "telemetry" function is enabled, the
transmitting machine automatically detects whether
the receiver is working. If it is still in the working
state, the transmitter needs to be confirmed before
it can be shut down normally! Avoid the transmitter
shutdown and cause the receiver to enter the fail
safe state, thus avoiding accidental damage and
loss of personal property caused by the model.
Receiver working voltage
External battery voltage
Telemetry
When the servo frequency is used to use the
digital servo, adjust the receiver output frequency to
match the operating frequency of the servo to better
play the servo performance.
Adjust the output frequency of the receiver, the
range is 50Hz~400Hz, and the setting is successful
when exiting.
Note:
Please do not change the servo frequency
parameters easily. Otherwise there is the possibility
of damage to the servo!
This function requires the transmitter and
receiver to be in normal linkage state, and the
setting can be effective!
Servo Frequency
Enter the interface:
→ Linkage Setting →
WFLY
Servo Frequency
Setting method:
Press the button-press the confirmation button to
call up the parameter adjustment button, the
up/down direction button to switch the button, and
press the enter button to adjust the parameter. The
Back button exits the interface and saves the
settings.
Touch Screen - Click on the value and click the
Add, Subtract, Reset button on the right to edit the
value. Click on the function name in the upper left
corner to exit the interface and save the settings.
R X
NO R M
4 . 2V
S
ervo Frequency
Vaule
5 0H z
0 0 : 0 6 : 5 9
R X
NORM
4 . 2 V
3
.
7V
External
3
.
7V
Receiver
Telemetry
0 0: 06: 59
Interface path:
Method 1:
→Linkage Setting→ Telemetry
WFLY
Method 2:Click the telemetry information box in
the standby interface.
Linkage Setting