WF-10T
Case Former
Machine Maintenance
9-91
9.8.7 Major Flaps Have a Tapered Gap or Gap / Overlap
Combination
•
Verify that case dimensions are square.
•
Verify that the tape unwind tension is not excessive. This can cause the major flaps to be
pulled back, causing a rear gap.
9.8.8 Major Flaps Fold, but Leading Edge Lifted by
Tape and Folded Back
•
Tape head may be set too low.
•
Check to ensure that the tape head bracket has not been set too low. Positioning is
normally factory pre-set. Adjustments may have to be made on a ‘trial and error’ basis
until optimum setting has been obtained.
If the tape head is mounted too low, slide the tape head out and remove it from the bracket. Then
use a wrench to loosen the bolts that secure the discharge end of the tape head bracket to the
main frame. Adjust the bracket up slightly in the adjustment slots and retighten the bolts.
Figure 9-2: Elevating the Tape Head Bracket
Summary of Contents for WF-10T
Page 2: ...WF 10T Case Former ...
Page 118: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 106 ...
Page 119: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 107 ...
Page 120: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 108 ...
Page 121: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 109 ...
Page 122: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 110 ...
Page 123: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 111 ...
Page 125: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 113 ...
Page 126: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 114 ...
Page 127: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 115 ...
Page 128: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 116 ...
Page 129: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 117 ...