WF-10T
Case Former
Case Size Adjustments
7-56
7.8
Case Blank Height Dimension ‘B’ Adjustment
Before making any machine adjustments, refer to
the shutdown procedure outlined in Section 6.5:
‘Shutdown’
. Measure the height of the case blank
on the scale provided and turn the Dimension ‘B’
hand crank until the top of the case reaches the
‘B’ pointer labels on the outfeed side of the
injector.
First, unlock the Dimension ‘B’ vertical
adjustment chain lock located on the top of the
machine arch. Note that the chain lock may be
on the opposite side to what is shown. Then
adjust the height of the case injector so that the
‘B’ line mark on the injector is level with the top of
the first case blank in the magazine. Ensure that
the tops of the stacked case blanks do not make
contact with the sensor mounted below the
injector.
The case blank height adjustment hand crank
can be located on either side of the machine
arch. For more information, contact your
Wexxar/BEL representative. Ensure that you re-
lock the vertical adjustment chain lock before
continuing.
Check the ‘S’ box for Satisfactory Performance and ‘US’ box for Unsatisfactory Performance.
Table 14: Dimension ‘B’ Adjustments
Size Adjustments
Case Blank Height Adjustment (Dimension ‘B’)
S
US
Unlock the vertical adjustment chain lock located on the top bar of the
frame arch.
Measure the outside dimension of the case blank height on the scale
provided.
Adjust the Dimension ‘B’ leadscrew using the detachable hand crank
provided until it reaches the ‘B’ pointer labels on the injector.
Ensure that you re-lock the vertical adjustment chain lock before
continuing.
Figure 7-10: Dimension ‘B’
Vertical Adjustment Chain Lock
Figure 7-11: Dimension ‘B’
Pointer on Injector Backplate
Figure 7-12: Dimension
‘B’ Hand Crank
Summary of Contents for WF-10T
Page 2: ...WF 10T Case Former ...
Page 118: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 106 ...
Page 119: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 107 ...
Page 120: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 108 ...
Page 121: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 109 ...
Page 122: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 110 ...
Page 123: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 111 ...
Page 125: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 113 ...
Page 126: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 114 ...
Page 127: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 115 ...
Page 128: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 116 ...
Page 129: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 117 ...