WF-10T
Case Former
Case Size Adjustments
7-68
Table 21: Full Cycle Sequence
Full Machine Cycle Sequence
STEP 1
Case Separator
UP / DOWN
STEP 2
Injector
DOWN / UP
Carriage
FORWARD
STEP 3
Jawplates
OPEN
STEP 4
Kicker Arm
UP
STEP 5
Kicker Arm
DOWN
STEP 6
Carriage
DOWN
STEP 7
Motor / Conveyors
ON
Carriage
RETRACT
Jawplates
CLOSE
STEP 8
Carriage
UP
The machine should form the case successfully in a step-by step manner. If a problem
should occur during any one of the above steps, analyze the reason for the problem and
adjust the machine accordingly. If necessary, refer to Section 9.3:
for further assistance.
8) When the machine successfully forms the case step-by-step in
JOG
mode, press the
‘AUTO MODE’
button to return to
AUTOMATIC CYCLE
mode. Then press the
‘START’
button to commence fully automatic operation. This completes the machine testing after
size adjustment.
Summary of Contents for WF-10T
Page 2: ...WF 10T Case Former ...
Page 118: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 106 ...
Page 119: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 107 ...
Page 120: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 108 ...
Page 121: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 109 ...
Page 122: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 110 ...
Page 123: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 111 ...
Page 125: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 113 ...
Page 126: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 114 ...
Page 127: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 115 ...
Page 128: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 116 ...
Page 129: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 117 ...