37
2)
Power indicator light of plasma power source (machine)
When whole system is on power, this indicator lights, when whole system is off power,
this indicator off.
3)
Inner setting of p
lasma power source (machine)
Connect the machine according to “Figure 7-2 multi plasma power working wiring
diagram”, the hardware of plasma power source supports one CNC maximally can
control 4 sets of plasma cutting power source (machine) at the same time. When multi
plasma power sources need to be equipped, open machine cover and set the N27/N25
on control board of PL01. (See Figure 5-1) The default setting is one CNC control one
cutting machine.
N54
XS16
XS17
N27
N52
N39
ON
1
2
ON
2
3
4
5
6
7
8
1
ON
2
3
4
1
短接
Figure 5-1 PL01 Hardware Default Settings
In Figure 5-1, the default setting of N27 toggle switch means this plasma power source
(machine) use “MOVE 1” as running signal output, all other move signal has no any of
functions on this machine.The default setting of N52 toggle switch means the ID number of
this plasma power source (machine) is 1.
Connect the machine according to “Figure 7-2 multi plasma power working wiring diagram”,
when one CNC control multi plasma power source (machine), need to open the machine
cover and as below steps:
① Plasma power source (machine) ID set: the cutting machine ID number correspond the
Summary of Contents for FLG-200HD
Page 9: ...5 Figure 2 1 System connection diagram ...
Page 43: ...39 Figure 5 2 SQK A1 front panel function Figure 5 3 SQK B1 front panel function ...
Page 74: ...70 4 System wiring diagram Figure 7 1 System wiring diagram ...
Page 77: ...73 2 Main circuit wiring diagram 2 Figure 7 4 FLG 200HD Main circuit wiring diagram 2 ...