10.3. GENERAL CONNECTION PROBLEMS
Error: No CAN Communication, Please RESET Communication
After correctly setting the configuration selection (see
) and clicking OK, the following error appears at the
bottom of WEST: “No CAN Communication, Please RESET Communication!”
a. See section on “Error: [COMM:ok][CAN:ok][ECU:No Communication]”
b. If the problem continues, disconnect the dongle from the dash harness
for one minute. Reconnect the dongle and click
RESET
at the lower
right hand corner of WEST.
Error: Project Name Mismatch! Project Revision Mismatch
“Project Name Mismatch! Project Revision Mismatch”:
a. The wrong A2W file was used. Go to
Load Configuration (A2W)
under the
File
menu and make sure that the correct A2W file is used.
see
Section 4.2 - Load Configuration
for details.
Error: An error has occurred while establishing a connection
to the server
This failure may occur when connecting to SQL Server 2005. Under the
default settings, SQL Server does not allow remote connections (Fig. 10.2).
This is caused by a missing or disabled component built into Windows. To
resolve this problem, please download and install Microsoft SQL Server 2005
Express Edition, which can be found at the Microsoft website at
http://www.microsoft.com/downloads/
Figure 10.2: SQL error message
WEST User Manual
73
Summary of Contents for WEST ADR 80/02
Page 1: ...WEST USER MANUAL V4 4 1031 Westport 15L System EPA07 EPA10 EPA13 ADR80 02 ADR80 03 ...
Page 2: ... This page is intentionally left blank ...
Page 19: ...2 2 SOFTWARE INSTALLATION Figure 2 5 Installation complete WEST User Manual 7 ...
Page 25: ...2 3 WEST HARDWARE SETUP Figure 2 10 USB connection problem message WEST User Manual 13 ...
Page 51: ...5 5 AUTOMATED NO LOAD TRIM ANT Figure 5 15 ANT screen WEST User Manual 39 ...
Page 72: ...7 2 CALIBRATION INFORMATION Figure 7 2 Calibration Information Window WEST User Manual 60 ...