130
250050 R1
6.42. Inspection Hatch Reinforcing Plate
1. For high wind applications, place the inspection hatch reinforcing plate under the roof sheet and secure with
5/16" x 1" hex flange bolts and nuts.
2. The flange on the plate must be located away from the hatch opening to minimize the possibility of
interference or injury with inspector.
3. The four outermost mounting holes are used for extra stiffening when the roof sheet width permits. Field
drill the roof sheet as needed.
Figure 98.
Inspection Hatch Reinforcing Plate Detail
Figure
32.
Inspection
Hatch
Reinforcing
Plate
Detail
REINFORCING PLATE
- 212199 UNDER ROOF SHEET
HATCH
MOUNTING BRACKET
STL/NEO
SEALING WASHER
5/16” x 1” HEX
FLANGE BOLT
REINFORCING PLATE
ROOF SHEET
EASYDRY® WIDE-CORR CENTURION® GRAIN BIN – GRAIN BIN DRYER