136
250050 R1
Figure 104.
Upright / Wall Sheet Bolt and Nut Orientation
Page E4
Assembly Tip:
It may be advantageous
to conduct pre-
assemblies during the
erection process. This
can be a real time saver.
LAMINATE
UPRIGHT
4”
LOCATOR
HOLES
UPRIGHT
SPLICE
3/8” x 1”
BOLT
3/8” NUT
ENSURE MATING UPRIGHTS
AND MATING LAMINATES SIT
SQUARELY ON TOP OF
EACH OTHER
DO NOT ALLOW MATING
UPRIGHTS AND MATING
LAMINATES TO OVERLAP
Bolt/Nut Orientation:
To allow for a good seal install the bolts from the inside of the
bin as shown for an externally stiffened bins. Install the bolts from the outside of the
bin for internally stiffened bins.
Upright/Splice Pre-Assemblies:
At the top of a bin, laminates are not utilized and a
splice is required to make the connection between mating uprights. The splice nests
inside the upright similar to a laminate. When pre-assembling uprights to splices,
insure that the splice goes on the top end of the upright, such that the label on the
bottom of the upright remains visible. Keeping the label visible will help prevent
subsequent errors. This practice will also prevent ground interference when
adjusting jack locations.
Upright and Laminate Assembly:
Uprights and laminates are designed to transfer vertical loads through an end to
end, butt connection. Ensure that mating uprights sit squarely on top of each other and do not overlap. Ensure that
mating laminates sit squarely on top of each other and do not overlap. Secure the joints with the nuts and bolts
provided. Failure to do so can result in structural failure.
Upright/Laminate Pre-Assemblies:
Laminates nest inside of uprights and are offset 4” above the uprights
. For
proper orientation, ensure that the labels on the upright and laminate are both
towards the bottom and that the locator holes in the middle portion of the upright and
laminate line up. Bolts can be placed in these locator holes to create a pre-
assembly.
All locator holes, located in the middle of the upright and laminate
flanges, need to be filled with bolts. These include holes in flanges that may
only have one thickness of material.
When properly assembled, both the upright label and the laminate label will remain
visible during the pre – assembly phase. Once assembled on the bin, the upright
label will be covered.
ALL BOLT HOLES IN
THE UPRIGHT AND
LAMINATE FLANGES
MUST BE FILLED
CL
WALL SHEET
BOLT
NUT
UPRIGHT
CORRECT
WRONG
Tip
It may be advantageous to conduct pre-assemblies during the installation process. This can be a real
time saver.
Figure 105.
Pre-Assembling Uprights/Splices
Page E4
LAMINATE
UPRIGHT
4”
LOCATOR
HOLES
UPRIGHT
SPLICE
3/8” x 1”
BOLT
3/8” NUT
ENSURE MATING UPRIGHTS
AND MATING LAMINATES SIT
SQUARELY ON TOP OF
EACH OTHER
DO NOT ALLOW MATING
UPRIGHTS AND MATING
LAMINATES TO OVERLAP
Bolt/Nut Orientation:
To allow for a good seal install the bolts from the inside of the
bin as shown for an externally stiffened bins. Install the bolts from the outside of the
bin for internally stiffened bins.
Upright/Splice Pre-Assemblies:
At the top of a bin, laminates are not utilized and a
splice is required to make the connection between mating uprights. The splice nests
inside the upright similar to a laminate. When pre-assembling uprights to splices,
insure that the splice goes on the top end of the upright, such that the label on the
bottom of the upright remains visible. Keeping the label visible will help prevent
subsequent errors. This practice will also prevent ground interference when
Upright and Laminate Assembly:
Uprights and laminates are designed to transfer vertical loads through an end to
end, butt connection. Ensure that mating uprights sit squarely on top of each other and do not overlap. Ensure that
mating laminates sit squarely on top of each other and do not overlap. Secure the joints with the nuts and bolts
provided. Failure to do so can result in structural failure.
Upright/Laminate Pre-Assemblies:
Laminates nest inside of uprights and are offset 4” above the uprights
. For
proper orientation, ensure that the labels on the upright and laminate are both
towards the bottom and that the locator holes in the middle portion of the upright and
laminate line up. Bolts can be placed in these locator holes to create a pre-
assembly.
All locator holes, located in the middle of the upright and laminate
flanges, need to be filled with bolts. These include holes in flanges that may
only have one thickness of material.
When properly assembled, both the upright label and the laminate label will remain
visible during the pre – assembly phase. Once assembled on the bin, the upright
label will be covered.
ALL BOLT HOLES IN
THE UPRIGHT AND
LAMINATE FLANGES
MUST BE FILLED
CL
WALL SHEET
BOLT
NUT
CORRECT
WRONG
Upright and Laminate Assembly
Uprights and laminates are designed to transfer vertical loads through an end to end, butt connection. Ensure
that mating uprights sit squarely on top of each other and do not overlap. Ensure that mating laminates sit
squarely on top of each other and do not overlap. Secure the joints with the nuts and bolts provided. Failure to
do so can result in structural failure.
EASYDRY® WIDE-CORR CENTURION® GRAIN BIN – GRAIN BIN DRYER