Parameters Configuration
98
9.5 Parametrization of the receiver with muting (with display)
The parameter configuration directly on the sensor takes place via the push buttons on the control panel.
Receiver
Menu down
Menu up
Apply
NOTE!
• If the parameter configuration is interrupted (e.g. due to an interruption in the power
supply), this causes the newly selected settings to be lost. In this case, the most recently
saved settings are active.
• To save changes to the parameter configuration permanently, the save function (see
must be used to write them to the device memory via RUN
SAVE. Otherwise, the changes will be lost when the device is restarted.
9.5.1 Default Settings
Function
Default settings
Restart inhibit
Off (safety operating mode / automatic restart)
Contactor Monitoring
Off
Beam coding
Off
Cascading
Off
Muting
Off
When muting is activated:
• Muting duration
300 s
• Belt stop function
Off
• Muting enable
Off
• Direction setting
Off
• Muting end through clearing of the
ESPE
Off
• Partial muting
Off
• Full Muting Enable
Off
• Gap suppression
Off
• Override
Off
Display and expert menu:
Display
Energy saving mode
Signal output
Acknowledgment prompt restart inhibit
Indicator lamp
Muting
Password protection
Active, 0000