Multi-Beam Safety Light Array
97
9.4.4 Parametrization of the Restart Inhibit, Contactor Monitoring and Coding
• The “Menu down” key (
) can be used to switch between the settings.
• The “Apply” key (
) changes the setting within the menu item:
– Restart inhibit: Switch between restart inhibit and contactor monitoring
– Contactor monitoring: Switch between contactor monitoring ON and contactor monitoring OFF
– Coding: Switch between coding ON and coding OFF
• The current set parameter configuration is indicated by different flashing frequencies:
Display during parameter
configuration
Meaning
Display during
operation
RES
Flashing, duty cycle 15 %
LED on
LED off
Restart inhibit OFF
(safety operating mode
ON)
RES
Flashing, duty cycle 85 %
LED on
LED off
Restart inhibit ON
RES
EDM
Flashing, duty cycle 15 %
LED on
LED off
Contactor monitoring
OFF
EDM
Flashing, duty cycle 85 %
LED on
LED off
Contactor monitoring
ON
EDM
CODE
Flashing, duty cycle 15 %
LED on
LED off
Coding OFF
CODE
Flashing, duty cycle 85 %
LED on
LED off
Coding ON
CODE
• To apply the settings, both keys ([
] and [
]) must be pressed at the same time until the red “ERROR”
LED goes out (approx. 2 s).
• By way of acknowledgment, all LEDs light up at the same time before the final setting is shown according
).
• If no acknowledgment takes place, the settings are dismissed and the most recent saved setting is applied
again.
NOTE!
• When setting the beam coding, the parameters must be configured on both the emitter
• To deactivate the beam coding, it must be deactivated on both the emitter and receiver