Diagnosis
144
E 013
Emitter /
receiver
Permanent
Supply voltage too high
Make supply voltage
available within the speci-
fied limits
E 020
Receiver
Permanent
OSSD A: Short to posi-
tive/ capacity too high
Resolve short to positive
E 021
Receiver
Permanent
OSSD A: Short to posi-
tive/ capacity too high
Resolve short to positive
E 022
Receiver
Permanent
OSSD A: Short to
ground/overload
Resolve short to ground
E 023
Receiver
Permanent
OSSD A: Short to
ground/overload
Resolve short to ground
E 024
Receiver
Permanent
OSSD B: Short to posi-
tive/ capacity too high
Resolve short to positive
E 025
Receiver
Permanent
OSSD B: Short to posi-
tive/ capacity too high
Resolve short to positive
E 026
Receiver
Permanent
OSSD B: Short to
ground/overload
Resolve short to ground
E 027
Receiver
Permanent
OSSD B: Short to
ground/overload
Resolve short to ground
E 028
Receiver
Permanent
Slave inputs: Different
switching status
Check slave connection,
inconsistent signals
E 029
Receiver
Permanent
Slave inputs: Different
switching status
Check slave connection,
inconsistent signals
E 030
Receiver
Permanent
• Contactor short to
positive
• Contactor does not
deactivate
• Incorrect parameter
configuration
• Check the contactor
function
• Configure the EDM
parameters correctly
E 031
Receiver
Permanent
• Contactor short to
positive
• Contactor does not
deactivate
• Incorrect parameter
configuration
• Check the contactor
function
• Configure the EDM
parameters correctly
E 032
Receiver
Permanent
• Contactor short to
ground
• Contactor does not
activate
• Incorrect parameter
configuration
• Check the contactor
function
• Configure the EDM
parameters correctly
E 033
Receiver
Permanent
• Contactor short to
ground
• Contactor does not
activate
• Incorrect parameter
configuration
• Check the contactor
function
• Configure the EDM
parameters correctly