Installation
88
7.2.4 Installation with Mounting Bracket ZEMX001
Figure 22: Installation with ZEMX001
7.2.5 Warning Strips
• Both the emitter and the receiver of the ESPE have a yellow warning strip in a side groove.
• If mounting is to take place over the side groove (see
section 7.2.2, page 87, section 7.2.3, page 87,
), it may be positioned on the wrong side depending on the installation situation.
• To remove the warning strip or to mount it on the opposite side, proceed as follows:
– Position a small screwdriver at the end of the warning strip and lever it carefully out of the groove.
– When removing, ensure that no components of the ESPE are damaged to guarantee correct function.
– To mount the warning strip, position it on the bottom end of the groove and click it in until it has engaged
over the entire length of the safety field.
• During this process, ensure that the profile, control panel, indicator lamp or glass are not damaged me-
chanically.
Figure 23: Yellow warning strip