![Wenglor SEFB Series Operating Instructions Manual Download Page 143](http://html1.mh-extra.com/html/wenglor/sefb-series/sefb-series_operating-instructions-manual_956883143.webp)
Multi-Beam Safety Light Array
143
13.3 Diagnosis Codes on the Receiver SEFB Muting
• A precise analysis of the current status of the ESPE is possible via the code on the 4-digit segment display
on the receiver.
• The following overviews describe the codes and measures for removing errors.
13.3.1 Codes for Information and Warnings
Code
Status
Description/cause
Measures
WED
Only initially
Contactor monitoring
signal present, but EDM
function is not active.
Parametrize contactor
monitoring
Always
Synchronous run (paral-
lel to other displays)
Not required
Always
Status display of the
inputs
Not required
Always
Status display muting
Not required
13.3.2 Codes for General Errors
Code
Affected
components
Status
Description/cause
Measures
002
Emitter /
receiver
Temporary, restarts after
2 s
Parameter configuration
request from normal op-
eration and error mode
003
Emitter /
receiver
Temporary, restarts after
2 s
Parameter configuration
request from normal op-
eration and error mode
Application errors
E 010
Emitter /
receiver
Temporary, restarts after
2 s
Supply voltage too low
Make supply voltage
available within the speci-
fied limits
E 011
Emitter /
receiver
Temporary, restarts after
2 s
Supply voltage too low
Make supply voltage
available within the speci-
fied limits
E 012
Emitter /
receiver
Permanent
Supply voltage too high
Make supply voltage
available within the speci-
fied limits