Project Engineering
44
5.2 Functions
This section contains important information on the functions of the ESPE and their usage
5.2.1 Functions Overview
Detailed descriptions of the individual functions can be found in the following sections.
Section
SEFB Muting
SEFB
Operational functions
Safety operating mode / automatic restart
X
X
Restart inhibit (RES)
X
X
Contactor monitoring (EDM)
X
X
Beam coding
X
X
Cascading
X
X
Range switching
X
X
Muting functions
Cross muting
X
—
Two sensor linear muting
X
—
Four sensor linear muting (sequence monitoring)
X
—
Four sensor linear muting (time monitoring)
X
—
Adjustable muting duration
X
—
Belt stop signal
X
—
Muting enable
X
—
Direction setting
X
—
Muting end through clearing of the ESPE
X
—
Partial muting
X
—
Full Muting Enable
X
—
Gap suppression
X
—
Override
X
—
Non-safety-related functions
Display setting (segment display)
X
—
Signal output
X
X
Integrated indicator lamp
X
—
Alignment aid (signal strength)
X
—
microSD memory card
X
—
Password protection
X
X (IO-Link)
IO-Link 1.1 interface
X
X
X = function included
− = function not included