6.2.6 Error Log Codes (For FilterQuick™ Controller Only)
CODE
ERROR MESSAGE
EXPLANATION
E03 ERROR TEMP PROBE
FAILURE
Temp probe reading out of range
E04
HI 2 BAD
High limit reading is out of range.
E05
HOT HI 1
High limit temperature is past more than 410°F (210°C), or in CE
countries, 395°F (202°C)
E06 HEATING
FAILURE
A component has failed such as controller, interface board, gas
valve, ignition module or open-high limit.
E07
ERROR MIB SOFTWARE
Internal MIB software error
E08
ERROR ATO BOARD
ATO board connection lost; ATO board failure
E09
ERROR PUMP NOT FILLING Dirty paper/pad and it needs changed or it was bypassed; filter
pump problem
E10
ERROR DRAIN VALVE NOT
OPEN
Drain valve was trying to open and confirmation is missing
E11
ERROR DRAIN VALVE NOT
CLOSED
Drain valve was trying to close and confirmation is missing
E12 ERROR RETURN VALVE
NOT OPEN
Return valve was trying to open and confirmation is missing
E13 ERROR RETURN VALVE
NOT CLOSED
Return valve was trying to close and confirmation is missing
E14
ERROR AIF BOARD
MIB detects AIF missing; AIF board failure
E15
ERROR MIB BOARD
Cooking controller detects MIB connections lost; Check software
version on each controller. If versions are missing, check CAN
connections between each controller; MIB board failure
E16
ERROR AIF PROBE
AIF RTD reading out of range
E17
ERROR ATO PROBE
ATO RTD reading out of range
E20
INVALID CODE LOCATION
SD card removed during update
E21
FILTER PAPER PROCEDURE
ERROR (Change Filter Paper)
25 hour timer has expired or a dirty filter may be causing an
incomplete filtration.
E22
OIL IN PAN ERROR
Oil may be present in the filter pan.
E25
RECOVERY FAULT
Recovery time exceeded maximum time limit. Recovery time
should not exceed 1:40 for electric.
E27
LOW TEMP ALARM
Oil temperature has dropped 30°F (17°C) lower than setpoint in
idle mode or 45°F (25°C) in cook mode. (This message may
appear if a product is dropped and the start cook button is not
pressed immediately or if too large of cook loads are dropped.)
E28
HIGH TEMP ALARM
Oil temperature has risen 40°F (22.2°C) higher than
setpoint. If temperature continues to rise, the high limit will shut the
burner off when temperature reaches 425°F (218°C) Non-CE or
395°F (202°C) CE.
E70
OQS TEMP HIGH
Oil temperature is too high for a valid OQS reading. Filter at a
temperature between 300ºF (149ºC) and 375ºF (191ºC).