6.1.3 Performing the Electrical Installation
Prerequisites
Check whether the following prerequisite is met:
■
The unit's connection point has been de-energized and locked and tagged out.
Checking the rating data and electrical connections
Follow the steps below to check the connection to the electrical system and the electrical connections:
Step
Procedure
Figure
1
Remove the unit's rear panel.
The circuit diagram and the spare parts list will be loca‐
ted inside the wiring compartment.
2
Check to make sure that the electrical rating data on the
nameplate matches the specifications in the circuit dia‐
gram and the characteristics of the building's electrical
system. Do not connect the combi oven unless all spec‐
ifications match.
3
Check all screw and crimp terminal connections on the
unit. The connections may have become loose during
transportation.
Performing the Electrical Installation
Follow the steps below to electrically connect your unit:
Step
Procedure
Figure
1
Connect the unit to an electrical ground system at the
intended connection point (1).
1
3
2
4
2
Check to make sure that the power cord is properly
connected to terminal block -X10 (2).
3
Make sure that the cable fitting (3) has a secure fit. This
fitting serves as a strain relief.
4
If necessary, reset the safety thermostat.
5
Put the unit's rear panel back in place and check that it
is mounted properly.
6
Connect the appropriate power plug to the power cord
(4).
7
Carry out the relevant country-specific electrical tests.
6 Installation
Installation Manual
53
Summary of Contents for Convotherm mini black easyTouch 10.10
Page 1: ...Combi Oven OES 6 10 mini easyTouch Installation manual UL USA Original ENG ...
Page 2: ......
Page 4: ......
Page 74: ......
Page 76: ...Combi Oven OES 10 10 mini easyTouch Installation manual UL USA Original ENG ...
Page 77: ......
Page 79: ......
Page 147: ......