CRUSH
HAZARD
CUTTING
HAZARD
CRUSH
HAZARD
CRUSH
HAZARD
CRUSH
HAZARD
CRUSH
HAZARD
ELECTRIC
HAZARD
FALLING
HAZARD
CRUSH
HAZARD
PINCH
HAZARD
PUNCTURE
HAZARD
ANTI-
STATIC
ALERT
IN THE CAB
̱
Push-buttons
̱
Acknowledge lights
̱
Emergency stop
̱
Telephone
̱
Alarm button
̱
Emergency light
̱
Gate(s)
̱
Gate switch(es)
̱
Gate Operator
IN THE HALLWAY
̱
Hall stations
̱
Interlocks
̱
In Use’ lights
̱
Car Here’ lights
̱
Proper leveling
̱
Proper clearance
͑
(between car & threshold)
IN THE HOISTWAY
̱
Clearance for travel cable
͑
͑
and all wiring
̱
Lubrication of rails
̱
Top Finals Switches
̱
Bleed Jack
̱
Warning
labels
̱
Clearance from car to hoistway
LABEL OR FILL IN
̱
Home Owners Guide
͑
͑
- Serial # & Dealer Info.
̱
Date and attach fl exible hose tag
̱
Date and attach rope tag
̱
2 pump tags
̱
GMV serial number tag
̱
Maintence Controlled Sheet
(Located in the Installation Manual)
IN THE MACHINE ROOM
̱
Fuses
̱
Remove all temporary jumpers
̱
Check all fasteners
̱
Leave area & equipment clean
̱
Slack Cable Switch
̱
Re-verify
Wire
Rope
Tension
̱
Verify LPS setting is correct
̱
Verify hydraulic oil is at proper level
̱
Verify there are no leaks in the system
̱
Interlock Key stored correctly
̱
Controller Door Storage Pouch:
-
Wiring
documents
- Microprocessor I/O chart
- Maintenance controlled chart
- Owner’s Manual
EDUCATE HOME OWNER
̱
Present and explain ‘Owner’s Guide’
̱
Demonstrate normal operating procedures
̱
Demonstrate emergency procedures
̱
Explain the operation of safety systems
̱
Explain the need for routine maintenance
1726 North Ballard Road, Suite 1 - Appleton, WI 54911 - 920.991.9082
Technical Support 855.804.5774 - [email protected]
PTS70036-D
12 FEB 2018
W
E
SERIES :
114 , 116
ELEVATOR RELEASE
CHECKLIST
HYDRAULIC MODELS
Page 70