LED Light Wiring
(With-out battery back up wiring)
Strip the LED extension cord back to the desired length. Wire per LED light schematic and national
and local codes terminating one LED light per terminal.
Verify that all LED lights work and adjust the dimmer to desired brightness.
Secure the LED Light covers and power supply to the ceiling of the elevator car with provided
hardware.
NOTE:
THERE ARE 9 SETS OF TERMINAL BLOCKS, EACH WITH 3 CONDUCTORS PER LIGHT. FOR SIMPLICITY, ONLY 1 SET IS SHOWN IN THIS
DIAGRAM. ALWAYS CONNECT ALL 3 WIRES (RED, BLACK, YELLOW), EVEN IF DIMMING IS NOT REQUIRED.
TO TURN LIGHTS ON AND OFF, SIMPLY ENERGIZE OR DE-ENERGIZE THE 120/240V AC INPUT TO THE EL2 POWER BOX.
ATTENTION: REMOVE ALL JUMPERS AS REQUIRED OUT OF THE LED LIGHT CONTROLLER BOX
CRUSH
HAZARD
CUTTING
HAZARD
CRUSH
HAZARD
CRUSH
HAZARD
FALLING
HAZARD
ANTI-
STATIC
ALERT
WITH-OUT BATTERY BACK-UP WIRING
(STANDARD)
3.
Power Supply
DC Wiring
RED
BLK
YE
L
RED
BLK
YE
L
RED
BLK
YE
L
RED
BLK
YE
L
RED
BLK
YE
L
RED
BLK
YE
L
RED
BLK
YE
L
RED
BLK
YE
L
RED
BLK
YE
L
9
8
7
6
5
4
3
2
1
Dim
m
er
Brown
Blue
Green & Yellow
Black
White
Yellow Dim Control
Red Dim Control
Black Dim Control
To Lights
120-240V
AC FEED
(Switched)
WARNING: DO NOT MIX AC AND DC WIRING. MAINTAIN BARRIER AS SHOWN BY THE DOTTED LINE
Input and output conductors are to be insulated for a minimum of 300V for all circuit connections.
1.
2.
Page 41