1726 North Ballard Road, Suite 1 - Appleton, WI 54911 - 920.991.9082
Technical Support 855.804.5774 - [email protected]
PTM30141-D
13 MAR 2018
W
E
CRUSH
HAZARD
CUTTING
HAZARD
CRUSH
HA
Z
ARD
CRUSH
HAZARD
CRUSH
HA
Z
ARD
CRUSH
HAZARD
ECO-SYSTEM
HAZARD
ELECTRIC
HAZARD
FALLING
HAZARD
CRUSH
HA
Z
ARD
PINCH
HAZARD
VALVE ADJUSTMENTS
SERIES :
114, 116
1) Main Pressure Relief Valve Adjustment
2) Levelling Speed Adjustment
3) Speed Transition Adjustment
4) Up Acceleration Adjustment
5) Down Speed Override
6) Pressure Gage Shutoff Screw
7) Manual Lowering Min. Pressure Adjustment
8) Pressure Balance
9) Down Speed Adjustment
10) Hand Pump Pressure Relief Valve Adjustment
11) Hand Pump Air Bleeder
12) Inspection Gage Fitting
VP) Pressure Valve
VMD) Down Solenoid Valve
VML) Full Speed Solenoid Valve
VRFP) Auxiliary Down Speed Control Valve
TROUBLESHOOTING TIP:
When energized, the coil stem becomes magnetized. Confi rm
this by placing a steel tool such as a wrench or screwdriver on
the stem.
VMD: Energized in Down Direction
VML: Energized in Both Up and Down Directions
VP: Energized in Up Direction
1
2
4
3
5
6
7
8
9
10
11
12
VRFP
VP
VML
HAND PUMP
MANUAL
LOWERING
CHECK VALVE
VMD
Page 60